The plant description
It now involves two stations: Power Plant III, systemic, operating six energy blocs of 1345 Mwe total installed power. Producing yearly some 5% of national electric power it plays a significant role in the security of the national energy system.
Attainable electric power - 1345 MW

Boiler OP - 650 (radial-flow, dust, single-drummed, with natural circulation at the boiler proper, double-lined with an inter-line hung on a carrying grate.) - 6 units
Producer- Rafako Racibórz
Max. capacity - 650 t steam/h
Pressure of steam: primary - 13,8 MPa
Pressure of steam: secondary - 2,34 MPa
Temperature of steam: primary/secondary - 540oC
Efficiency - 93%
Producer- Rafako Racibórz
Max. capacity - 650 t steam/h
Pressure of steam: primary - 13,8 MPa
Pressure of steam: secondary - 2,34 MPa
Temperature of steam: primary/secondary - 540oC
Efficiency - 93%
Turbine No. 5 - 13 K 220 (impulse, axial, tri-cylinder)
Producer - Zamech Elbląg
Max. power - 220 MW
Steam pressure - 12,8 MPa
Temperature of steam: primary/secondary - 535oC
Producer - Zamech Elbląg
Max. power - 220 MW
Steam pressure - 12,8 MPa
Temperature of steam: primary/secondary - 535oC
Turbine No. 1, 2, 3, 4 i 6 - 13 K 225 (impulse, axial, tri-cylinder)
Producer - Zamech Elbląg
Max. power - 225 MW
Steam pressure - 12,8 MPa
Temperature of steam: primary/secondary - 535oC
Producer - Zamech Elbląg
Max. power - 225 MW
Steam pressure - 12,8 MPa
Temperature of steam: primary/secondary - 535oC
Generator No. 1, 2, 3, 4, 5, 6 - GTHW - 230 (synchronous, tri-phased)
Producer - ABB DOMEL Wrocław
Apparent power - 270,6 MVA
Apparent power - 230 MW
Stator's current - 9919 A
Efficiency - 98,5%
Power Factor - 0,85
Producer - ABB DOMEL Wrocław
Apparent power - 270,6 MVA
Apparent power - 230 MW
Stator's current - 9919 A
Efficiency - 98,5%
Power Factor - 0,85
The second plant is Power Plant II, a modern heat station running two fluidal boilers and one dust boiler, producing electric power and heat combined of maximum power equal to 390,2 MWt and 190 Mwe respectively.
Electric power of the turbine set installed - 190 MW
Attainable electric power of the power plant - 190 MW
Attainable thermal power in association - 321 MWt
Attainable electric power of the power plant - 190 MW
Attainable thermal power in association - 321 MWt
Fluidization boiler CFB - 650 (with circulation bed , atmospheric furnace, natural water circulation, single-drummed.) - 2 units
Producer - Froster Wheeler
Max. capacity - 260 t steam/h
Steam pressure - 13,7 MPa
Steam temperature - 540oC
Producer - Froster Wheeler
Max. capacity - 260 t steam/h
Steam pressure - 13,7 MPa
Steam temperature - 540oC
Efficiency - 91%
Boiler PK-10p (dust, hydro-tubular, completely screened, with natural water circulation, double-drummed)
Producer - Podolska Fabryka Kotłów (Soviet Union)
Max. capacity - 230 t steam/h
Steam pressure - 10,7 MPa
Steam temperature - 510oC
Efficiency - 91%
Producer - Podolska Fabryka Kotłów (Soviet Union)
Max. capacity - 230 t steam/h
Steam pressure - 10,7 MPa
Steam temperature - 510oC
Efficiency - 91%
Turbine No. 2 and 3 - 13 CK 70 (heat and condensing, steam, axial, single-cylinder, with a single-stage exchanger of the lattice water)
Producer - ABB Zamech
Electric rated power - 70 MW
Attainable thermal power - 115 MWt
Steam pressure - 13 MPa
Steam temperature - 535oC
Producer - ABB Zamech
Electric rated power - 70 MW
Attainable thermal power - 115 MWt
Steam pressure - 13 MPa
Steam temperature - 535oC
Turbine No. 1 - 10 CK 60 (heat and condensing, steam, impulse, axial, single-cylinder, with a single-stage exchanger of the lattice water)
Producer - ABB Zamech
Electric rated power - 60 MW
Attainable thermal power - 91 MWt
Steam pressure - 10 MPa
Steam temperature - 510oC
Producer - ABB Zamech
Electric rated power - 60 MW
Attainable thermal power - 91 MWt
Steam pressure - 10 MPa
Steam temperature - 510oC
Generator No. 1
Producer - Elektrosiła (Soviet Union)
Rated power - 58,8 MVA
Stator's current - 3240 A
Stator's voltage - 10,5 kV
Power factor - 0,85
Producer - Elektrosiła (Soviet Union)
Rated power - 58,8 MVA
Stator's current - 3240 A
Stator's voltage - 10,5 kV
Power factor - 0,85
Generator No. 2, 3
Producer - ABB DOMEL Wrocław
Rated power - 87,5 MVA
Stator's current - 4393 A
Stator's voltage - 11,5 kV
Power factor - 0,8
Producer - ABB DOMEL Wrocław
Rated power - 87,5 MVA
Stator's current - 4393 A
Stator's voltage - 11,5 kV
Power factor - 0,8
Heat generating stations
- exchangers XPS1, XPS2 of the power - 2 x 46 MWt
- under-turbine exchanger TG1 - 91 MWt
- under-turbine exchangers TG2, TG3 - 2 x 115 MWt
Maximum parameters of the lattice water at the peak:
temperature - 135/70oC and pressure 1,4/0,5 MPa
temperature - 135/70oC and pressure 1,4/0,5 MPa
Output units of our plant are state-of-the-art, operative, and meet environmental demanding standards to produce electric and heat energy effectively and ecologically. As a result, it generates the highest profits among the power plants of the Corporation. At the same time, we have always been the leaders in new technological solutions, environment friendly, innovative, and modern management systems. In consequence, all the above facts contribute to our position of a mainstay of PKE SA and our experience, we are always ready to share with others, serves all power plants of the Corporation.